Relevant for
This warning means the printer has detected that the heatbreak thermistor is disconnected or providing invalid readings. The message shown is: Heatbreak thermistor is disconnected. Inspect the wiring.
The heatbreak thermistor monitors the temperature of the cold end of the hotend, the heatbreak. If the printer cannot read its value, it may indicate a disconnected cable, a faulty thermistor, or a problem on the board the sensor is connected to (the LoveBoard or the Dwarf Board).
Error name: Heatbreak thermistor fail
Error code: #31822 (CORE One) #35822 (CORE One L) #17822 (XL) #26822 (MK4S) #13822 (MK4) #27822 (MK3.9S) #21822 (MK3.9)
In case of any doubts in identifying the cause, or if the warning persists after checking connections and cables, do not hesitate to contact our Support for further assistance.