The printer is displaying the message: Incorrect RPM reading of the fan. Please check its wiring and connection.
Error name: Fan failure
Error code: #10126
This error indicates that one of the fans of the printer is not working correctly. It measured the RPM of the SL1/S fans and found one of them out of the accepted range.
Starting from firmware 1.7.0, this error replaces Fan failure #10106 (SL1/SL1S) [進行中の翻訳].
The SL1/SL1S has three fans:
If the warning appears, please follow the maintenance steps for the fan that generated the issue: SL1/SL1S maintenance. When doing that, also check the cable connections of the fan to the mainboard.
SL1 electronics wiring |
SL1S electronics wiring |
Run the Selftest once again. For SL1, navigate to LCD menu -> Settings -> Recalibration; for SL1S, navigate to LCD menu -> Settings -> Calibration -> Selftest. In case the fan also fails during the self-test, switch the connection of two of the fans, and see if the warning will be transferred to the new fan. If the error is transferred, the fan that had the warning originally may need to be replaced.
In case you find some parts are faulty, please order them using our e-shop, then follow the service guide(s):
How to replace a blower fan (SL1) [進行中の翻訳]
How to replace a blower fan (SL1S) [進行中の翻訳]
If you have a question about something that isn't covered here, check out our additional resources.
And if that doesn't do the trick, you can send an inquiry to [email protected] or through the button below.