What happened?

Implausible SuperFINDA reading. This error happens when a filament is detected by the SuperFINDA sensor although the MMU doesn’t have a record of any filament being loaded. It is unsure of which position the filament is loaded in so it can’t perform the unload automatically.

This usually happens, if the user was loading a filament manually not using the menu/buttons, or if the printer was restarted while performing a certain load/unload operation without finishing it first.

How to fix it?

  • Unload a filament manually or clear the sensors from any filament to continue.
  • Verify the superFINDA calibration.
  • Use only the menu on the printer to load or unload a filament during regular use.