Version 6.10.1

28.08.2026

Summary

  • New features
    • Support for the new Prusa XL+
    • Contactless tool offset calibration [XL+]
    • Nozzle thermal expansion compensation [XL/+]
    • Immediate stop on filament runout [6.8.1]
    • Guided calibration order [6.8.1]
    • Filament compatibility checks in more places [6.8.1]
    • Reworked tool mapping screen [6.6.0]
    • Tool mapping is preserved when reprinting a job [6.9.0]
    • Screen for unloading or changing all filaments at once [6.6.0]
    • Redesigned error screens (BSOD/RSOD) [6.5.1]
    • Crash dumps can be saved after a RSOD [6.9.0]
    • Load All and Unload All in the Filament menu [6.9.0]
    • Experimental Fast draw display mode [6.5.1]
  • Changes and improvements
    • The bed moves down after finishing, pausing or stopping a print [XL/+]
    • Reorganized menus [6.8.1, 6.9.0]
    • More reliable probing and mesh bed leveling [6.6.0]
    • Spool Join now unloads the filament [6.6.0]
    • Improved filament change between different materials [6.5.7]
    • Reworked filament sensor selftest [6.5.1]
    • Calibrations and Tests can continue with a single test at a time [6.5.1]
    • Custom filament names may contain lowercase letters [6.8.1]
    • Nozzle diameters of 0.1 mm and 0.15 mm can be selected [6.5.1]
    • Side LED dimming can be set to Never, Always or Idle [6.5.0]
  • Fixes
    • Fixed layer shifts during high-speed curved moves [6.5.3]
    • Fixed input shaper axis assignment [6.5.3]
    • Fixed input shaper calibration exciting the wrong axes [6.5.7]
    • Fixed a crash when printing files with more than 1024 objects [6.5.7]
    • Fixed not restoring original temperature on filament runout/mid-print change [6.8.1]
    • The last file in a folder was not visible, and related file list fixes [6.8.1]
    • The printer no longer beeps on boot in Silent mode [6.8.1]
    • An upward swipe on the touchscreen is no longer registered as a tap [6.8.1]

Version 6.4.2

03.06.2026

Fixes

  • Fixed not loading custom Connect certificates

Version 6.4.1

20.04.2026
  • Calibración de phase stepping mejorada
  • Problemas de homing corregidos con ninguna herramienta seleccionada
  • Movimientos fijos del cambiador corregidos cuando están afectados por la anulación de la velocidad de avance por parte del usuario
  • Comprobaciones menos estrictas de la limpieza de boquilla para evitar falsos errores de limpiar la boquilla
  • Umbrales del selfttest del ventilador de impresión menos estrictos para reducir los falsos fallos
  • Problema conocido - Modo pánico resultando en una BSOD

Version 6.2.6

03.09.2025

Resumen

  • Reducción de la frecuencia de actualización de la pantalla para mejorar la estabilidad
  • Sensibilidad reducida a las fluctuaciones de la calefacción de la base en la XL
  • Correcciones para fallos BSOD poco frecuentes durante el manejo del filamento

Version 6.2.5

28.04.2025
  • Corregidos cuelgues durante cambios rápidos de herramienta consecutivos