hotend | Buscar

Methods for replacing the Nextruder Hotend… hotend&show=all | Buscar Error mintemp hotend #13208 (MK4) #21208 (MK3.9) Si dispones de un multímetro, es posible comprobar la…

Hotend thermal runaway #23204 (MK3.5)

If there is a positive temperature change it means that the hotend thermistor is working and detecting the temperature change. Most likely, the issue stems from the hotend heater.…

Hotend preheat error #23202 (MK3.5)

If there is a positive temperature change it means that the hotend thermistor is working and detecting the temperature change. Most likely, the issue stems from the hotend heater.…

Hotend mintemp error #23208 (MK3.5)

If there is a positive temperature change it means that the hotend thermistor is working and detecting the temperature change. Most likely, the issue stems from the hotend heater.…

Hotend Heater Overcurrent #17322

Before performing any of the procedures, ensure the printer is fully cooled down, switched off, and disconnected from the mains.

Changing or replacing the Nextruder Hotend

Changing or replacing the Nextruder Hotend | Prusa Knowledge Base Español Login Prusa Research as Impresoras 3D Materiales Piezas y accesorios Software Modelos 3D Aplicaciones…

Hotend maxtemp error #23206 (MK3.5)

Make sure the thermistor and heater are properly plugged into the electronics board. You can verify this from the dedicated step in our assembly manual. Check if the fuses are…

Extruder Maxtemp error #17206 (XL)

The hotend thermistor is rated to be 100 kΩ at 25 °C. To be realistic, with a varying temperature between 20 °C and 30 °C, you can expect a wider range of readings (~80-125 kΩ).…

Selftest failed (MK3.5/S)

Heatbed & Hotend test In this step of the selftest, the hotend and heatbed will be heated to their maximum capacity to check if all cables are correctly connected and will not…

How to replace the hotend fan (XL Multi-tool)

How to replace a PSU (XL) Como reemplazar un calentador del fusor (XL Mono Cabezal) Cómo lubricar los pasadores de acoplamiento de la Original Prusa XL (MultiCabezal) How to replace…

Loadcell troubleshooting

Alternatively, the loadcell testing can be initiated in LCD Menu -> Control -> Calibration & Tests -> Loadcell Test.

How to replace a hotend assembly (CORE One)

Comenzar el montaje Step 1 of 20 (Chapter 5 of 8) Modo pantalla completa Contenidos Comentarios How to replace a hotend assembly (CORE One) Dificultad Moderada Idiomas disponibles…

Hotend atascado (XL)

Un primer signo de obstrucción de la boquilla es que el filamento no se extruye de forma uniforme, se enrosca y se pega a la boquilla. Clic del extrusor El hotend o la boquilla…

Prusa Knowledge Base

Instalado en ambos, fusor y base calefactable. El termistor del fusor está dentro de un cartucho que se introduce en el bloque calentador y se sujeta con un tornillo. El termistor…