JA
  • English
Login

How to replace the Prusa Nozzle (CORE One)

How to replace the Prusa Nozzle (CORE One)

How to replace the Prusa Nozzle (CORE One)
Relevant for:
Last updated 17 days ago
How to replace the Prusa Nozzle (CORE One)
 Difficulty
Easy
 Steps
22
 Available languages
EN
Introduction
Introduction
This guide will take you through the Prusa Nozzle replacement on your Original Prusa CORE One.
The following instructions are compatible with all Prusa Nozzle diameters.
All necessary parts are available in our eshop prusa3d.com.
Note that you have to be logged in to have access to the spare parts section.
Printer Preparation (Part 1)
Printer Preparation (Part 1)
Printer Preparation (Part 1)
Printer Preparation (Part 1)
Close the printer’s door.
Unload the filament. Visit the menu Filament and select Unload filament.
プリンタからフィラメントを取り外します。
Remove the filament spool from the printer.
Ensure the printer has completely cooled down.
On the printer screen, navigate to Preheat -> COOLDOWN and wait for the temperatures to drop to ambient levels. This may take several minutes.
Printer Preparation (Part 2)
Printer Preparation (Part 2)
Printer Preparation (Part 2)
Printer Preparation (Part 2)
Open the menu Control > Move Axis > Move Z and set it to 100 mm or more.
Wait until the heatbed moves down.
Turn the printer off using the switch on the back.
Disconnect the printer from power.
Top Cover Removal
Top Cover Removal
Top Cover Removal
Top Cover Removal
Open the printer. From the inside, reach for the nylon rivet on the front right of the top cover. Push it out to unlock it.
Then, remove the rivet from the outside.
On the far right side of the cover, remove the other nylon rivet using the same technique.
Remove the top cover.
Heatbed Protection
Heatbed Protection
Before proceeding any further, it is recommended to protect the heatbed first!
Use a piece of fabric or other material thick enough to cover the heatbed. This will ensure you won't damage (scratch) the surface during the process.
Nextruder Uncovering
Nextruder Uncovering
Nextruder Uncovering
Let’s move onto the left side of the Nextruder.
Using the T10 key, remove the two M3x12rT screws holding the side cover.
Remove the cover.
Cables Disconnecting
Cables Disconnecting
Cables Disconnecting
Cables Disconnecting
各コネクターには安全ラッチがあります。取り外す前に、ラッチを押す必要があります。さもないと、コネクターが破損する恐れがあります。
Disconnect the hotend heater cable.
Disconnect the hotend thermistor cable.
Hotend Assembly Removal
Hotend Assembly Removal
Hotend Assembly Removal
Hotend Assembly Removal
Remove the hotend cables from the cable guide.

Grasp the hotend with your hand.

もう片方の手で2本のサムスクリューを緩めます。完全に外す必要はなく、数回回すだけで十分です。
Watch out, the hotend assembly may fall out!
ホットエンドアセンブリをヒートシンクからスライドして外します。
Prusa Nozzle Removal
Prusa Nozzle Removal
Prusa Nozzle Removal
Prusa Nozzle Removal
Remove the silicone sock from the heater block.
Use the 13-16 wrench to hold the heater block securely.
Use the 7mm cutout in the universal wrench to grasp and loosen the nozzle.
Manually unscrew and remove the Prusa nozzle from the hotend assembly.
Prusa Nozzle Installation
Prusa Nozzle Installation
Prusa Nozzle Installation
Prusa Nozzle Installation
Screw the new nozzle fully into the heater block until it touches the heater block surface.
Hold the heater block securely using the 13-16 wrench.
Use the 7mm cutout in the universal wrench to tighten the nozzle against the heater block. Avoid applying excessive force!
指定トルク値は1.5Nm(13.3lb-in)です。トルクレンチの使用を推奨します。
Optionally, install the silicone sock.
Hotend Assembly Parts Preparation
Hotend Assembly Parts Preparation
For the following steps, please prepare:
Hotend assembly (1x)
The CORE One hotend assembly has a Nextruder Silicone Sock installed by default. It is optional, and you can remove it at any time.
For more information, read the article Nextruder Silicone Sock.
The default nozzle on the CORE One is the 0.4mm HF, (High Flow version) labeled CHT
Hotend Insertion
Hotend Insertion
Hotend Insertion
Hotend Insertion

Locate the corresponding opening on the bottom of the extruder heatsink and fully insert the hotend into the heatsink.

At the same time, keep the hotend cables pointing to the front, at a slight angle.

The assembly must fit into the recess in the fan shroud with appropriate clearance
Keep pushing the hotend assembly upward and tighten both thumbscrews to secure it in place.
Ensure the hotend is fully inserted into the heatsink. It should align as shown in the picture and must not protrude below the fan shroud.
Nozzle Insertion Check
Nozzle Insertion Check
Verify that the nozzle is fully inserted into the heatsink. The copper ring on the nozzle should not be visible if properly seated.
If not fully inserted, it can cause poor heat transfer, potentially leading to nozzle clogs.
ノズルの位置を調整するには、サムスクリューを緩めてノズルの位置を変え、ホットエンドアセンブリーを押し上げながらネジを締め直します。
Hotend Cables Guidance
Hotend Cables Guidance
Locate the cable guide (plastic hook) behind the thumb screws. Guide the thermistor cable through the channel first. Then insert the hotend heater cable.
Cables Connection
Cables Connection
Cables Connection
Cables Connection
ホットエンドサーミスタをLoveBoardの左上のスロットに接続します。
ホットエンドヒーターをLoveBoard 上部の黒いスロットに接続します。
Nextruder Cover
Nextruder Cover
Nextruder Cover
Nextruder Cover
Organize the cables to ensure they do not protrude.
Attach the cover to the left side of the Nextruder assembly.
Using the T10 Torx key, fix the cover in place with two M3x12rT screws.
Remove the protective material from the heatbed.
Top Cover
Top Cover
Top Cover
Now, we can reinstall the top cover.
Align the cover with the metal frame in the far-right corner.
Align the cover with the recess in the front part as well
Secure the cover in place using two nylon rivets in the marked openings.
Turning the Printer On
Turning the Printer On
Turning the Printer On
Close the door.
Connect the printer to electricity.
プリンターの電源を入れます。
Nozzle Set Up
Nozzle Set Up
Nozzle Set Up
Nozzle Set Up
このステップは、ノズルの直径やタイプを変更した場合のみ重要です。
Visit the Settings > Hardware > Printhead menu
使用するノズル径を選択してください。(例:0.25 / 0.3 / 0.4 / 0.5 / 0.6 / 0.8)
On CORE One, the 0.40 mm nozzle is the stock size.
Turn on the Silicone sock option if you are using one.
Select a nozzle type.
On CORE One, the High Flow nozzle is a default.
Final check
Final check
Final check
To verify the connections, navigate to Control > Temperature > Nozzle Temperature and set it to above 200°C.
Return to the main screen and check the bottom bar to ensure the temperature is rising as expected.
Great job! You can now resume using your printer.
Was this guide helpful?

Comments

Still have questions?

Still have questions?

If you have a question about something that isn't covered here, check out our additional resources.
And if that doesn't do the trick, you can send an inquiry to [email protected] or through the button below.

Contact us