What happened? 

On the Prusa CORE One, communication with the xBuddy extension board is achieved using the MODBUS protocol. In MODBUS, there are two types of devices: the master and the slave, also known, respectively, as client and server. On Prusa CORE One firmware, the master is the xBuddy, and each slave is called puppy

If one of the puppies does not respond to a request from xBuddy within a specified time period, the printer will show the message: "Waiting for puppies to start timed out".

Error name: Puppy run timeout

Error code: #31522

The error indicates most likely a configuration problem that might have stemmed from the firmware, or a faulty connection of the xBuddy extension board. 

How to fix it? 

Ensure the printer is cold, switched off, and disconnected from the mains before accessing its electronics. 

Access the xBuddy and xBuddy extension boards by loosening six M3x4bT bolts to remove the cover. Once visible, check the boards for visible damage on their surface, and check the connection between xBuddy and xBuddy extension for any irregularities.