On the Prusa CORE One, communication with the xBuddy extension board is achieved using the MODBUS protocol. In MODBUS, there are two types of devices: the master and the slave, also known, respectively, as client and server. On Prusa CORE One firmware, the master is the xBuddy, and each slave is called puppy.
Each puppy is identified by the printer based on its type. If the puppy type is different than expected, the printer will show the message "Unknown puppy type".
Error name: Puppy unknown type
Error code: #31516
The error indicates most likely a configuration problem that might have stemmed from the firmware, or a faulty connection of the xBuddy extension board.
Access the xBuddy and xBuddy extension boards by loosening six M3x4bT bolts to remove the cover. Once visible, check the boards for visible damage on their surface, and check the connection between xBuddy and xBuddy extension for any irregularities.
![]() | ![]() |