What happened? 

The printer is showing the message "Heatbed tile no. #: Unexpected temperature peak detected". 

Error name: MB peak temp

Error code: #17255

How to fix it? 

The error message includes the number of the affected heatbed tile. The error might indicate an issue with the cable connecting the indicated heatbed tile with the modular bed electronics, or with the heatbed tile itself. 

A visual inspection

Check that the indicated heatbed cable is correctly connected with the modular bed electronics, and with the heatbed tile, and reseat the connection. 

Check the heatbed tile for physical damage, for example, a scratch on any heatbed tile surface, or a cable in bad status on the bottom of a heatbed tile. The heatbed tiles are numbered as shown in the below picture.

Swap the cables

On the heatbed side, swap the heatbed tile connection indicated on the error with another heatbed tile connector, and check if the indicated heatbed tile number in the error changes, or remains the same after the swap. 

If the error changes to another heatbed tile number after the cables swap, then the cable is causing the error. 

If the error is still the same as before, with the same error code, and on the same heatbed tile number after the swap, most likely the heatbed tile is causing the error. 

If your findings are different than these two cases, or in case of any doubts, do not hesitate to contact our customer support.