EN
  • Čeština
  • Español
  • Italiano
  • Deutsch
  • Polski
  • Français
  • 日本語
Login

Hotend mintemp error #13208 (MK4) #21208 (MK3.9)

Menu
Relevant for:
Last updated 6 months ago
This article is also available in following languages: 
CSPLDEESITFRJA

What happened?

The printer is showing the message "Check the print head thermistor wiring for possible damage."

Error name: Hotend mintemp error

Error code: #13208 (MK4) #21208 (MK3.9)

This error is shown when the printer's nozzle temperature drops below 5 ºC at any point. If this happens during a print, the print will be stopped.

How to fix it?

Extruder inspection

This error is usually caused by the hotend thermistor

Access the LoveBoard. Check if the thermistor is connected correctly and if there is no damage along the cable length.

If you have a multimeter, it is possible to check the resistance of the cables to verify if they are damaged. For that, use our Multimeter usage guide.

xBuddy board inspection

Make sure that the Loveboard main cable is correctly connected to the xBuddy board.

Was this article helpful?

Comments

Still have questions?

Still have questions?

If you have a question about something that isn't covered here, check out our additional resources.
And if that doesn't do the trick, you can send an inquiry to [email protected] or through the button below.

Contact us