Prusa CORE One je uzavřená tiskárna s dvířky. Pro tisk je nutné, aby byly dveře zavřené.
Zavřená dvířka zlepšují kvalitu tisku, ale také zajišťují vaši bezpečnost, pokud jde o možné zranění pohybujícími se součástmi.
Postup
To calibrate the door sensor position, navigate to LCD Menu -> Control -> Calibrations & Tests -> Door sensor calibration. An introductory message is shown on the screen, select Calibrate.
The printer prompts to first close the door. Once the door is closed, press Continue.
Then, the printer prompts to open the door, and gradually tighten the sensor tension screw. Tighten the tension bolt by half-turn for each iteration. After each adjustment, observe the door sensor switch emerging from the front profile hole.
Once tightened, press Continue. Follow the in-screen instructions, the printer can instruct to further tighten the tension screw, to loosen it, or to continue to a successive step.
When the printer prompts you, place your hand as shown in the screen picture below.
Once the sensor is calibrated, you should hear an audible click from the door sensor area when regularly opening and closing the door.
After the calibration, the status can be checked in LCD Menu -> Info -> Sensor Info -> Door Sensor.